-
Fire Products
- Fire Extinguishers
- Hose Reels and Cabinets
- Fire Blankets
- Fire Hose
- Fire Resisting Safes and Cabinets
- Emergency Response
- Akron Products
-
Breathing Apparatus
- Escape Breathing Apparatus
- Self Contained Breathing Apparatus (SCBA)
- Airline Breathing Apparatus
- Emergency Air System: Pro-Cab
- Resuscitation: Manual and Automatic Resuscitation System (MARS)
- Facemasks
- Filtered Respiratory Systems
- Military Facemasks
- Self Contained Breathing Apparatus (SCBA) Cylinders
- Communications Devices
- Personal Alarm Safety System Automatic Distress Signal Unit and Telemetry Systems
- Thermal Imaging
- Gas Detection - Portable
- Gas Detection - Fixed
- Passive Fire Products
- Residential Fire Products
-
Fire Systems
-
Detection and Evacuation
- MX Technology
- VIGILANT® MX1 Fire Indicator Panel
- VIGILANT® F3200 Fire Indicator Panel
- VIGILANT® MX4428 Fire Indicator Panel
- VIGILANT® QE90 Emergency Warning and Intercommunication System (EWIS)|
- Tyco 614 Series Fire Detectors
- MX Series Addressable Modules
- MX VIRTUAL® Multi-Sensor Fire Detectors
- Warning Systems Ancillaries – Audio
- Warning Systems Ancillaries – Visual
- T-GEN 50 Tone Generator
- Mk2 Audio Visual Indicator
- MINERVA® S200 PLUS Triple Waveband Infrared Flame Detection
- STI-CIS Speech Intelligibility Meter
- VESDA systems
- Fire Sprinkler Systems
- Gaseous Agents
- Water Spray Deluge Systems
- Water Mist Systems
- Foam Systems
- Vehicle Fire Suppression
- Kitchen Fire Suppression
-
Detection and Evacuation
- Design Install Commission
-
Services
- Servicing and Maintenance
- Compliance and Testing
- Specialised Fire Protection Solutions
-
Fire Safety Training
- Fire Extinguisher Training Using Portable Fire Fighting Equipment
- Breathing Apparatus Training
- Confined Space Entry Training
- Fire Safety Adviser Training QLD only
- Fire Safety Officer Training Level 1 NSW only
- Spill Response Training
- Emergency Control Organisation Warden Training
- Chief and Deputy Chief Warden Training
- Evacuation Exercise
- General Staff Emergency Awareness Training
- First Aid Training
- Warden Refresher Training
- Lay Flat Hose Training
- Fire Monitoring
- VESDA System Service
- Consultancy
- Gateway National Support Centre
- Industry Capabilities
- About Us
- Contact Us
-
News and Information
- Media Room
-
FireWire Newsletter
- FireWire Subscription
- Firewire Back Issue Order
- FireWire Issue 29 - March 2012
- FireWire Issue 28 - December 2011
- FireWire Issue 27 - September 2011
- FireWire Issue 26 - June 2011
- FireWire Issue 25 - March 2011
- FireWire Issue 24 Dec 2010
- FireWire Issue 23 October 2010
- FireWire Issue 22 June 2010
- FireWire Issue 21 March 2010
- FireWire Issue 20 September 2009
- FireWire Issue 19 July 2009
- FireWire Issue 18 March 2009
- FireWire Issue 17 November 2008
- FireWire Issue 16 September 2008
- FireWire Issue 15 June 2008
- Events
- Resource Centre
Aquasonic™ system – high pressure solution
The Aquasonic™ water-atomizing fire suppression system is a total flood system designed to protect Class B flammable liquid hazards in machinery spaces, both insulated and non-insulated combustion turbine enclosures, generator enclosures, and flammable liquid storage.
The Aquasonic™ system can protect a potential hazard with a free volume up to 260 m3 with two atomizers that use low pressure, dual flow, supersonic atomization technology to create a minimum 10-minute discharge plume of water droplets that are the optimum size to suppress a Class B fire.
When sprayed within an enclosure, the Aquasonic™ atomizer spray pattern expands slightly and the water droplets are primarily distributed (circulated) around the space via the high velocity atomizing media discharge. As the high velocity discharge plume of water droplets approaches the floor, or other horizontal obstruction, a large majority of the plume is diverted laterally, as well as vertically upwards, to fill the spaces between the core spray patterns and above the atomizers. The circulation characteristics of the Aquasonic™ atomizer plume result in rapid, homogenous distribution of water droplets throughout the protected environment. The Aquasonic™ system has been fire tested within compartmentalized areas and found effective for the suppression of a wide variety of exposed and shielded Class B hydrocarbon pool, spray, and cascading pool fires.
The Aquasonic™ system utilizes water droplets as the suppression agent. These droplets can effectively be applied in total flooding fire suppression applications having a free volume up to and including 9200 ft3 (260 m3). Applications include:
- Machinery Spaces
- Both Insulated and Non-Insulated Combustion Turbine Enclosures
- Generator Enclosures
- Flammable Liquid Storage
Related Products
Related Documents
Ansul® Aquasonic™ Datasheet
Ansul® Aquasonic™ Product Brochure
At Wormald we offer a range of fire equipment, fire safety products and fire services for the Australian market.
- Terms of Use
- Privacy Policy
- Information Collection Statement
- Compliments & Complaints
- Trading With Wormald
- Fire Extinguishers
- Alarms & Evacuation Systems
- Fire Systems
- Fire Services
- Fire Safety Training
- Sitemap
© Copyright Tyco Australia Pty Limited 2010. All Rights Reserved