-
Fire Products
- Fire Extinguishers
- Hose Reels and Cabinets
- Fire Blankets
- Fire Resisting Safes and Cabinets
- Emergency Response
- Akron Products
-
Breathing Apparatus
- Escape Breathing Apparatus
- Self Contained Breathing Apparatus (SCBA)
- Airline Breathing Apparatus
- Emergency Air System: Pro-Cab
- Resuscitation: Manual and Automatic Resuscitation System (MARS)
- Facemasks
- Filtered Respiratory Systems
- Military Facemasks
- Self Contained Breathing Apparatus (SCBA) Cylinders
- Communications Devices
- Personal Alarm Safety System Automatic Distress Signal Unit and Telemetry Systems
- Thermal Imaging
- Gas Detection - Portable
- Gas Detection - Fixed
- Passive Fire Products
- Residential Fire Products
-
Fire Systems
-
Detection and Evacuation
- MX Technology
- VIGILANT® MX1 Fire Indicator Panel
- VIGILANT® F3200 Fire Indicator Panel
- VIGILANT® MX4428 Fire Indicator Panel
- VIGILANT® QE90 Emergency Warning and Intercommunication System (EWIS)|
- Tyco 614 Series Fire Detectors
- MX Series Addressable Modules
- MX VIRTUAL® Multi-Sensor Fire Detectors
- Warning Systems Ancillaries – Audio
- Warning Systems Ancillaries – Visual
- T-GEN 50 Tone Generator
- Mk2 Audio Visual Indicator
- MINERVA® S200 PLUS Triple Waveband Infrared Flame Detection
- STI-CIS Speech Intelligibility Meter
- VESDA systems
- Fire Sprinkler Systems
- Gaseous Agents
- Water Spray Deluge Systems
- Water Mist Systems
- Foam Systems
- Vehicle Fire Suppression
- Kitchen Fire Suppression
-
Detection and Evacuation
- Design Install Commission
-
Services
- Servicing and Maintenance
- Compliance and Testing
- Specialised Fire Protection Solutions
-
Fire Safety Training
- Fire Extinguisher Training Using Portable Fire Fighting Equipment
- Breathing Apparatus Training
- Confined Space Entry Training
- Fire Safety Advisor Training QLD only
- Fire Safety Officer Training Level 1 NSW only
- Spill Response Training
- Emergency Control Organisation Warden Training
- Chief and Deputy Chief Warden Training
- Evacuation Exercise
- General Staff Emergency Awareness Training
- First Aid Training
- Warden Refresher Training
- Lay Flat Hose Training
- Fire Monitoring
- VESDA System Service
- Consultancy
- Gateway National Support Centre
- Industry Capabilities
- About Us
- Contact Us
-
News and Information
- Media Room
-
FireWire Newsletter
- FireWire Subscription
- Firewire Back Issue Order
- FireWire Issue 28 - December 2011
- FireWire Issue 27 - September 2011
- FireWire Issue 26 - June 2011
- FireWire Issue 25 - March 2011
- FireWire Issue 24 Dec 2010
- FireWire Issue 23 October 2010
- FireWire Issue 22 June 2010
- FireWire Issue 21 March 2010
- FireWire Issue 20 September 2009
- FireWire Issue 19 July 2009
- FireWire Issue 18 March 2009
- FireWire Issue 17 November 2008
- FireWire Issue 16 September 2008
- FireWire Issue 15 June 2008
- Events
- Resource Centre
MINERVA® S200 PLUS Triple Waveband Infrared Flame Detection
The MINERVA® S200 PLUS family of infrared flame detectors lend themselves to intrinsically safe and flameproof environments when the source of fire is flammable/volatile areas, such as; in process areas, aircraft hangers, petro-chemical facilities.
The MINERVA® S200 PLUS flame detectors are the latest step in over 30 years experience of developing and manufacturing infrared, solar blind and multi-channel infrared flame detectors with low power consumption and high false alarm immunity. The MINERVA® S200 PLUS incorporates the patented dual solar blind feature of the S100 and S200 flame detectors which have over 26,000 installations world-wide.
The MINERVA® S200 PLUS range of advanced flame detectors is the most comprehensive range available. The devices are available in both “Intrinsically Safe” or “Flameproof” versions incorporating a variety of electrical interfaces, which are all supported through the existing range of MINERVA® fire control panels.
Intrinsically Safe Applications
The intrinsically safe models are suffixed by the letter “ i “ and meet the requirements of EN50020 part 7 and are BASEEFA certified EEx ia IIC T5. As part of an intrinsically safe circuit, it is suitable for zones 0,1 and 2 where group IIC gases or lesser hazards can be continuously present in explosive concentrations.
Flameproof Applications
The flameproof models are suffixed by the letter “f” and meet the requirements of EN50018 and are BASEEFA certified EEx d IIC T6. The detectors are suitable for zones 1 and 2 where group IIC gases or lesser hazards can be intermittently present in explosive concentrations.
Features
- IECEx Approval (IECEx facilitate international trade in equipment and services for use in explosive atmospheres, while maintaining the required level of safety)
- Unrivalled blackbody rejection over a wide range of source temperatures
- Triple waveband infrared solar blind flame detection for optimum false alarm immunity
- Discrimination of optical faults (dirty windows) from other faults in the built-in self test
- Range adjustable to 50 metres for a 0.1m2 n-heptane pan fire
Related Services
Fire Safety Training
IT&T Industry Capabilities
Hotel and Leisure industry capabilities
Transport and Logistic industry capabilities
Healthcare industry capabilities
Marine industry capabilities
Related Documents
At Wormald we offer a range of fire equipment, fire safety products and fire services for the Australian market.
- Terms of Use
- Privacy Policy
- Information Collection Statement
- Compliments & Complaints
- Trading With Wormald
- Fire Extinguishers
- Alarms & Evacuation Systems
- Fire Systems
- Fire Services
- Fire Safety Training
- Sitemap
© Copyright Tyco Australia Pty Limited 2010. All Rights Reserved